Revert Fix FrskyX failsafe hold/no pulse inversion

This commit is contained in:
pascallanger
2019-09-22 20:00:04 +02:00
parent 6503469ddd
commit 96bc4f7cdf
2 changed files with 5 additions and 5 deletions

View File

@@ -19,7 +19,7 @@
#define VERSION_MAJOR 1
#define VERSION_MINOR 2
#define VERSION_REVISION 1
#define VERSION_PATCH_LEVEL 80
#define VERSION_PATCH_LEVEL 81
//******************
// Protocols
@@ -405,8 +405,8 @@ enum MultiPacketTypes
#define IS_WAIT_BIND_off ( ( protocol_flags2 & _BV(7) ) ==0 )
// Failsafe
#define FAILSAFE_CHANNEL_HOLD 0
#define FAILSAFE_CHANNEL_NOPULSES 2047
#define FAILSAFE_CHANNEL_HOLD 2047
#define FAILSAFE_CHANNEL_NOPULSES 0
//********************
//** Debug messages **
@@ -806,7 +806,7 @@ Serial: 100000 Baud 8e2 _ xxxx xxxx p --
2047 +125%
Values are concatenated to fit in 22 bytes like in SBUS protocol.
Failsafe values have exactly the same range/values than normal channels except the extremes where
0=hold, 2047=no pulse. If failsafe is not set or RX then failsafe packets should not be sent.
0=no pulse, 2047=hold. If failsafe is not set or RX then failsafe packets should not be sent.
*/
/*
Multimodule Status