From 47f792c169222ce50f9400a1ff42fda824f412fa Mon Sep 17 00:00:00 2001 From: pascallanger Date: Wed, 30 Dec 2015 02:07:53 +0100 Subject: [PATCH] Update README.md --- README.md | 18 +++++++++--------- 1 file changed, 9 insertions(+), 9 deletions(-) diff --git a/README.md b/README.md index af9f2a4..51fd817 100644 --- a/README.md +++ b/README.md @@ -37,7 +37,7 @@ Options are: - Range: test range by setting the transmission power to the lowest value Note: - - there is 2 versions of serial protocol either 8 or 16 channels. 16 channels is the latest version. Make sure to use the right version based on your version of er9x/ersky9x. + - there are 2 versions of serial protocol either 8 or 16 channels. 16 channels is the latest version. Make sure to use the right version based on your version of er9x/ersky9x. ###Telemetry Telemetry is available for er9x and ersky9x TX. @@ -49,7 +49,7 @@ To enable telemetry on Turnigy 9X or 9XR you need to modify your TX following on ##Protocols ###TX ID -Each protocol is using a 32bits ID generated randomely at first power up. There are little chances to get a duplicated ID. +Each protocol is using a 32bits ID generated randomly at first power up. There are little chances to get a duplicated ID. It's possible to generate a new ID using bind button on the Hubsan protocol during power up. @@ -80,7 +80,7 @@ Dial|Protocol|Sub_protocol|RF Module Notes: - The dial selection must be done before the power is applied. -- The protocols and subprotocols can be personnalized by modifying the source code. +- The protocols and subprotocols can be personalized by modifying the source code. ####Using serial input with er9x/ersky9x Protocol|Sub_protocol|RF Module @@ -126,7 +126,7 @@ Note: ###Protocol details Extended limits supported: -125%..+125% can be used and will be transmitted. Otherwise the default is -100%..+100% only. -Autobind protocol: you do not need to press the bind button at power up to bind, this is done automaticaly. +Autobind protocol: you do not need to press the bind button at power up to bind, this is done automatically. ####BAYANG Autobind protocol @@ -197,7 +197,7 @@ Extended limits supported Telemetry enabled for A0, A1, RSSI -Option=fine frequency tunning, usually 0 or -41 based on the manufacturer boards +Option=fine frequency tuning, usually 0 or -41 based on the manufacturer boards CH1|CH2|CH3|CH4|CH5|CH6|CH7|CH8|CH9|CH10|CH11|CH12|CH13|CH14|CH15|CH16 ---|---|---|---|---|---|---|---|---|----|----|----|----|----|----|---- @@ -273,7 +273,7 @@ RF modules can be installed for protocols need only. Example: if you only need t You also need some [antennas](http://www.banggood.com/2_4GHz-3dBi-RP-SMA-Connector-Booster-Wireless-Antenna-Modem-Router-p-979407.html) and [cables](http://www.banggood.com/10cm-PCI-UFL-IPX-to-RPSMA-Female-Jack-Pigtail-Cable-p-924933.html). ###Microcontroller -The main program is running on a ATMEGA328 running @16MHz and 3.3V. +The main program is running on an ATMEGA328 running @16MHz and 3.3V. An [Arduino pro mini](http://www.banggood.com/Wholesale-New-Ver-Pro-Mini-ATMEGA328-328p-5V-16MHz-Arduino-Compatible-Nano-Size-p-68534.html) can be used to build your own Multimodule. Using stripboard: @@ -295,7 +295,7 @@ or build your own board using SMD components and an associated PCB: Attention: All modules are 3.3V only, never power them with 5V. ###Radio integration -You can 3D print your box (detalis [here](http://www.rcgroups.com/forums/showpost.php?p=33294140&postcount=2034)): +You can 3D print your box (details [here](http://www.rcgroups.com/forums/showpost.php?p=33294140&postcount=2034)): ![Screenshot](http://static.rcgroups.net/forums/attachments/1/1/5/4/3/7/t8462144-54-thumb-Multi_case_9XR.jpg?d=1448575289) ![Screenshot](http://static.rcgroups.net/forums/attachments/1/1/5/4/3/7/t8462145-106-thumb-Multi_case_v1.jpg?d=1448575293) @@ -320,7 +320,7 @@ Use a tool like [AVR Burn-O-Mat](http://avr8-burn-o-mat.aaabbb.de/) to set the f - High Fuse 0xD2 - Extended Fuse 0x05 -This will make sure your ATMEGA328 is well configured and the global TX ID is not erased at each updates. +This will make sure your ATMEGA328 is well configured and the global TX ID is not erased at each updates. ##Troubleshooting @@ -331,7 +331,7 @@ This will make sure your ATMEGA328 is well configured and the global TX ID is n - on: normal operation. ###Bind -Make sure to follow the following procedure: press the bind button, apply power and then release it after 1sec. The LED should be blinking fastly indicating a bind status and then fixed on. It's normal that the LED turns off when you press the bind button, this behavior is not controlled by the Atmega328. +Make sure to follow the following procedure: press the bind button, apply power and then release it after 1sec. The LED should be blinking fast indicating a bind status and then fixed on. It's normal that the LED turns off when you press the bind button, this behavior is not controlled by the Atmega328. ###Protocol selection For serial, leave all 4 selection pins unconnected.