Preparation for new protocol MT99XX (includes H7)

This commit is contained in:
pascallanger 2016-02-01 11:41:36 +01:00
parent 38c6330a2a
commit 08dc0db2e2
3 changed files with 59 additions and 35 deletions

View File

@ -414,6 +414,12 @@ static void protocol_init()
next_callback=initESKY();
remote_callback = ESKY_callback;
break;
#endif
#if defined(MT99XX_NRF24L01_INO)
case MODE_MT99XX:
next_callback=initMT99XX();
remote_callback = MT99XX_callback;
break;
#endif
}
@ -496,7 +502,7 @@ static void module_reset()
case MODE_DEVO:
CYRF_Reset();
break;
default: // MODE_HISKY, MODE_V2X2, MODE_YD717, MODE_KN, MODE_SYMAX, MODE_SLT, MODE_CX10, MODE_CG023, MODE_BAYANG, MODE_ESKY
default: // MODE_HISKY, MODE_V2X2, MODE_YD717, MODE_KN, MODE_SYMAX, MODE_SLT, MODE_CX10, MODE_CG023, MODE_BAYANG, MODE_ESKY, MODE_MT99XX
NRF24L01_Reset();
break;
}

View File

@ -42,6 +42,7 @@
#define V2X2_NRF24L01_INO
#define YD717_NRF24L01_INO
//#define FRSKYX_CC2500_INO
//#define MT99XX_NRF24L01_INO
//Update this table to set which protocol and all associated settings are called for the corresponding dial number
static const PPM_Parameters PPM_prot[15]=
@ -116,6 +117,10 @@ static const PPM_Parameters PPM_prot[15]=
NONE
MODE_ESKY
NONE
MODE_MT99XX
MT99
H7
YZ
RX_Num value between 0 and 15

View File

@ -27,23 +27,25 @@
enum PROTOCOLS
{
MODE_SERIAL = 0, // Serial commands
MODE_FLYSKY = 1, // =>A7105 / FLYSKY protocol
MODE_HUBSAN = 2, // =>A7105 / HUBSAN protocol
MODE_FRSKY = 3, // =>CC2500 / FRSKY protocol
MODE_HISKY = 4, // =>NRF24L01 / HISKY protocol
MODE_V2X2 = 5, // =>NRF24L01 / V2x2 protocol
MODE_DSM2 = 6, // =>CYRF6936 / DSM2 protocol
MODE_DEVO =7, // =>CYRF6936 / DEVO protocol
MODE_YD717 = 8, // =>NRF24L01 / YD717 protocol (CX10 red pcb)
MODE_KN = 9, // =>NRF24L01 / KN protocol
MODE_SYMAX = 10, // =>NRF24L01 / SYMAX protocol
MODE_SLT = 11, // =>NRF24L01 / SLT protocol
MODE_CX10 = 12, // =>NRF24L01 / CX-10 protocol
MODE_CG023 = 13, // =>NRF24L01 / CG023 protocol
MODE_BAYANG = 14, // =>NRF24L01 / BAYANG protocol
MODE_FRSKYX = 15, // =>CC2500 / FRSKYX protocol
MODE_ESKY = 16, // =>NRF24L01 / ESKY protocol
MODE_FLYSKY = 1, // =>A7105
MODE_HUBSAN = 2, // =>A7105
MODE_FRSKY = 3, // =>CC2500
MODE_HISKY = 4, // =>NRF24L01
MODE_V2X2 = 5, // =>NRF24L01
MODE_DSM2 = 6, // =>CYRF6936
MODE_DEVO =7, // =>CYRF6936
MODE_YD717 = 8, // =>NRF24L01
MODE_KN = 9, // =>NRF24L01
MODE_SYMAX = 10, // =>NRF24L01
MODE_SLT = 11, // =>NRF24L01
MODE_CX10 = 12, // =>NRF24L01
MODE_CG023 = 13, // =>NRF24L01
MODE_BAYANG = 14, // =>NRF24L01
MODE_FRSKYX = 15, // =>CC2500
MODE_ESKY = 16, // =>NRF24L01
MODE_MT99XX=17, // =>NRF24L01
};
enum Flysky
{
Flysky=0,
@ -95,6 +97,12 @@ enum CG023
YD829 = 1,
H8_3D = 2
};
enum MT99XX
{
MT99 = 0,
H7 = 1,
YZ = 2
};
#define NONE 0
#define P_HIGH 1
@ -400,6 +408,7 @@ Serial: 100000 Baud 8e2 _ xxxx xxxx p --
Bayang 14
FrskyX 15
ESky 16
MT99XX 17
BindBit=> 0x80 1=Bind/0=No
AutoBindBit=> 0x40 1=Yes /0=No
RangeCheck=> 0x20 1=Yes /0=No
@ -442,6 +451,10 @@ Serial: 100000 Baud 8e2 _ xxxx xxxx p --
CG023 0
YD829 1
H8_3D 2
sub_protocol==MT99XX
MT99 0
H7 1
YZ 2
Power value => 0x80 0=High/1=Low
Stream[3] = option_protocol;
option_protocol value is -127..127